Curtain Wall Dartek CW
Curtain wall for securing high-risk sites
DarTek CW is a high-performance range of Curtain Wall that has been specially designed to provide protection against gunfire from fire arms. It can be installed on any building requiring ballistic protection.
Perfectly suited for use with sensitive or high-risk environments – such
as Government buildings, headquarters or cash centers whilst maintaining an elegant appearance and saving energy.
DarTek CW is a high-performance range of Curtain Wall that has been specially designed to provide protection against gunfire from fire arms. It can be installed on any building requiring ballistic protection.
Perfectly suited for use with sensitive or high-risk environments – such
as Government buildings, headquarters or cash centers whilst maintaining an elegant appearance and saving energy.
INDUSTRIES
Key Features
- Elegant appearance.
- Finishes and dimensions versatility.
- Certified bullet resistance up to FB6 according EN 1522.
- Certified manual attack resistance up to level RC4 according EN 1627.
- Reduction of the consumption of energy in the building.
In view of heightened risks and the emergence of new threats – such as terrorism and organised crime – it is now vital that sensitive sites implement reinforced protective measures in order to guard against attacks, secure their infrastructure and ensure the continuity of their business.
At Head offices, Police stations or administrative buildings, attacks can have fatal consequences. Special attention should therefore be paid to physically securing the sites, particularly to contain any attacks using fire arms. This involves installing curtain wall with high ballistic resistance so as to deter people from committing malicious acts and guarantee maximum security.
Resistance
The Curtain Wall DarTek CW have been tested and certified to withstand:
- Ballistic attacks up to level FB6 in accordance with the European standard EN 1522.
- Manual attacks up to level RC4 in accordance with the European standard EN 1627.
- Design for reduction of the consumption of energy in the building.
Thermal regulations
Our Curtain Walls offer a real barrier against thermal exchange. They fight against the strong temperature variations between outside / inside on a site, whether it is:
– Cold (reduce the loss of heat in winter)
– Warm (limiting reheating of the inside of the building, limiting the use of air conditioning systems and reducing the consumption of energy in the building.
Finishing
To harmonise with every types of architecture, all the component metallic profiles of the curtain wall are available in a wide choice of color (chart RAL) As well as a wide choice of clear or reflecting glazing.