ClearSec FOS

Manual full-height turnstile for internal and external use

Passage in both directions electronically controlled. ClearSec FOS 90 offers a standard electromechanical head able to prevent two passages at one time, equipped with damper for a silent mechanism and smooth operation.

In the event of an emergency or power-off scenario, the unit can be configured fail-safe i.e. rotor freely  rotates or fail-lock i.e. rotor locks. This option is available either in one or both directions of passage.

Passage in both directions electronically controlled. ClearSec FOS 90 offers a standard electromechanical head able to prevent two passages at one time, equipped with damper for a silent mechanism and smooth operation.

In the event of an emergency or power-off scenario, the unit can be configured fail-safe i.e. rotor freely  rotates or fail-lock i.e. rotor locks. This option is available either in one or both directions of passage.

Clearsec

INDUSTRIES

  • Ic4
  • Ic3
  • Ic2
  • Ic1

Key Features

  • Dot Card reader integration
  • Dot Switching interface COMR1
  • Dot Serial interface RS485
  • Dot Remote console
  • Dot Internal lighting
  • Dot Extra Canopy

Mechanism

Electro-mechanical head mechanism:

  • Positive action lock to prevent two passages at one time
  • Self centering mechanism to ensure complete rotation in the rest position
  • Anti backup device to prevent reverse rotation once the head moved 30° from rest position
  • Hydraulic damper to ensure a smooth and quiet operation

Power Failure / Fire Alarm

In the event of a power failure the rotor wings will remain locked in the fail-lock configuration or can freely rotate in the fail-safe configuration. Fail-Lock or Fail- Safe configuration is available in one or both directions and must be specified at time of order placement.

Note that head mechanism fail state will be the same as power failure choice. Input facility available for voltage free contact to effect fire alarm fail state (COMR1 option required).

Power Supply / Power Rating

230Vac 50Hz or 115Vac 60Hz
Power Rating 50VA, 50 + 50 VA for Double unit Without lights option

Operating Temperature / IP Rating / MCBF / MTTR

-5 to +50°C (RH 95% not condensing) / IP34 / 1.5M cycles / less than 30min

Flow Rates (approximate figures)

  • Insertion Type Reader, 12 passages per minute
  • Swipe Type Reader, 15 passages per minute
  • Proximity Reader “Hands Free”, 17 passages per minute

LCM02 microprocessor control logic:
• One input for opening/locking the mechanism in each
direction
• Two protected outputs for control of the opening/locking
solenoids
• Four protected outputs for piloting way mode indicators
• Two 0V output relays indicating availability of use in either
direction
• Two 0V outputs to count passage in either direction
• Adjustable time out via parameter change: i.e. Go signal
is cancelled if the passage is not completed within a preset time (standard default 8sec)

  • Card reader integration
  • Switching interface COMR1
  • Serial interface RS485
  • Remote console
  • Internal lighting
  • Extra Canopy
  • Battery back-up

LCM02 microprocessor control logic:
• One input for opening/locking the mechanism in each
direction
• Two protected outputs for control of the opening/locking
solenoids
• Four protected outputs for piloting way mode indicators
• Two 0V output relays indicating availability of use in either
direction
• Two 0V outputs to count passage in either direction
• Adjustable time out via parameter change: i.e. Go signal
is cancelled if the passage is not completed within a preset time (standard default 8sec)

  • Card reader integration
  • Switching interface COMR1
  • Serial interface RS485
  • Remote console
  • Internal lighting
  • Extra Canopy
  • Battery back-up

Some of our clients

Microsoft Logo
Nextdc Pt 4000w
Hilton Zurich Airport Logo
Kemba Credit Union Logo
Hanover Bank Logo
Spisestuerne Logo
Bouwmaat Logo
Ff
Favicon New
Organisation 6988 Scaled 300x130
Download1