Automated Fare Collection
Ticketing Solution
Automated fare collection for metro, bus and train networks
Robust and Durable
Stainless steel cabinet construction and retractable polyurethane coated metal panels
Fast and Secure
High passenger throughput with accurate prevention of fraudulent entry
Metro Bi-Parting Gate
Tailgating prevention and high throughput
Unobtrusive design with retractable flaps that does not discriminate between passengers with special needs or luggage.
Unobtrusive design with retractable flaps that does not discriminate between passengers with special needs or luggage.
Contact a Product Expert
View Details
Mode of Operation
- Controllable via interface connection to AFC control system.
- On receiving a signal from the AFC control system, or remote control, the flap leaves open (Normally Closed NC).
- If an unauthorised person tries to tailgate or attempts to enter from the opposite direction, the internal alarm system is activated.
- If within the pre-set timeout no passage has occurred, the flaps will close and reset.
Security Features
- High-Performance Fraud Detection through sophisticated and proven algorithm
- Strategically concealed 16x TX and RX infrared photocell arrays
- More than 40 different passage scenarios handled
- Intrusion | Tailgating | Piggybacking
- Wrong way direction | Leave aisle timeout | Anti-crawling leaf flap barrier
- Passenger with hand-carried luggage | Passenger with wheeled trolley luggage
Single Person Detection
Tailgating Prevention
Wrong Way Prevention
Safety Features
- Dedicated independent safety detection circuit to EN12100 and EN 13849-1 to prevent the moving panels from closing on any passenger.
- Emitter / receiver infrared sensors technology monitoring the area immediately around the moving flaps.
- Logic voltage 24 VAC.
- Voltage free contact input for Fire Alarm fail state.
- Moving panels constructed from semi-rigid polyurethane mounted on to a steel core to limit potential damage to passenger (option).
- Safety for users (including finger entrapment and impact force) compliant with EN16005.
- Wide walkway for wheel chair or easier access.
- Accompanied wheelchair or child passage management.
We have achieved a more uniform, fast and efficient passenger flow while ensuring security
Jan Skov, Head of Security, Billund Airport
Read Full Story
Key Specifications
- Design and Construction: Standard passage width (550mm) and Wide passage width (900mm) available. Available also as Combi-centre cabinet with narrow (550mm) passage on one side and wide (900mm) passage width on the other side.
- Reliability Figures: Robust design to withstand high volumes in peak hour.
- Investment: Guaranteed long-term investment protection and profitabilty.
- MCBF: >12.000.000 cycles.
- MTTR: <30 min.
- Operating Speeds: Standard lane opening and closing 0.5s, wide passage opening and closing 0.7s.
- Flow Rates: Up to 60 passengers/minute throughput (Dependent upon reading technology and response times).
- Authorisation: stacking up to 8 authorisations.
Installation
- Dimensions (HxLxW): 1072mm, 1930mm, 300mm (central max width).
- Option: 200 mm width cabinet option available.
- Footprints: Rectangular or tapered footprints available.
- Power Supply: 230VAC 50Hz or 115 VAC 60Hz.
- Fire Signal: Input for voltage free contact.
- Operating Temperature: 0 to +45°C (RH 95% not condensing), -20°C with heating system (optional).
- Low Running Costs: <0.5%/pa of installation base (Based upon actual 12 month field survey data).
- IP Rating: IP 43.
Key Specifications
Installation
- Design and Construction: Standard passage width (550mm) and Wide passage width (900mm) available. Available also as Combi-centre cabinet with narrow (550mm) passage on one side and wide (900mm) passage width on the other side.
- Reliability Figures: Robust design to withstand high volumes in peak hour.
- Investment: Guaranteed long-term investment protection and profitabilty.
- MCBF: >12.000.000 cycles.
- MTTR: <30 min.
- Operating Speeds: Standard lane opening and closing 0.5s, wide passage opening and closing 0.7s.
- Flow Rates: Up to 60 passengers/minute throughput (Dependent upon reading technology and response times).
- Authorisation: stacking up to 8 authorisations.
- Dimensions (HxLxW): 1072mm, 1930mm, 300mm (central max width).
- Option: 200 mm width cabinet option available.
- Footprints: Rectangular or tapered footprints available.
- Power Supply: 230VAC 50Hz or 115 VAC 60Hz.
- Fire Signal: Input for voltage free contact.
- Operating Temperature: 0 to +45°C (RH 95% not condensing), -20°C with heating system (optional).
- Low Running Costs: <0.5%/pa of installation base (Based upon actual 12 month field survey data).
- IP Rating: IP 43.