TG1000 Groundtrack Automatic Sliding Gate

Finished to a high standard and comply with current safety requirements

Groundtrack Sliding Gates are automatic sliding gates that come in a variety of widths and heights to suit site requirements.

The ground track sliding gates are manufactured from RHS sections of sufficient strength to suit operating requirements which are dependent upon the gates opening width, height, type of infill (wind loading/ weight) and the level of security required.

Groundtrack Sliding Gates are automatic sliding gates that come in a variety of widths and heights to suit site requirements.

The ground track sliding gates are manufactured from RHS sections of sufficient strength to suit operating requirements which are dependent upon the gates opening width, height, type of infill (wind loading/ weight) and the level of security required.

Groundtrack Automatic Sliding Gate TG1000

Key Features

  • Dot High quality coating system
  • Dot Environmentally durable
  • Dot Galvanised/Zinc sprayed or powder/plastic coated
  • Dot Custom built to client specification
  • Dot Operational under power failure conditions
  • Dot Manual Override facility

The tracked gate requires a shorter run back area than a cantilever gate making it possible for installation in restricted spaces/areas

The gate leaf is held in the vertical plane by a set of guide posts with adjustable guide rollers and driven by a rack and pinion. All drive units mechanically lock the leaves in position with the option for a positive locking mechanism.

A variety of sizes, infills and finishes are available to suit individual site applications and gates can span openings of up 12 metres, subject to gate height and infill.

The gates are finished to a high standard and comply with current safety requirements and come complete with hold to run button & force limiters as standard.

NB Sliding gates are designed to be used with vehicles only and pedestrians should be provided with an alternative entrance or exit.

This is a specialist security product and is designed for use with vehicles only and a full site risk assessment must be carried out at design stage to ensure that all relevant safety systems are included.

Where the gate control point is remote from the installation, we strongly recommend the fitting of a recordable CCTV system. For safety reasons pedestrians, cyclists and motorcycles are should not to use a gate controlled roadway.

  • High quality coating system
  • Galvanised/Zinc sprayed and powder/plastic coated
  • Manual override facility
  • Bespoke built units
  • Environmentally durable
  • Custom built to client specification
  • Ease of installation
  • Operational under power failure conditions

Basic Power Requirements:
230v Single phase 50Hz supply 230V/400V 3 phase (option) 110V (option). The incoming mains supply to the control panel is normally single- phase 220/250 V, but three phase 400V may be required depending on the design length and weight of the gate.

Control:
Basic gate is a push button – hold to run, alternative access control systems can be accommodated.

Dimensions:
Dimensions range from 3m to 12m Clear width openings and heights are normally 2.1m or 2.4m, infills and panels available are dependant on height and weight of gate.

Safety:
When deciding to install a sliding gate A full site risk assessment should be undertaken prior to the design and installation of the gate, to ensure that all the appropriate safety measures have been addressed:

Safety Options – In accordance with the workplace (Health, Safety and Welfare) regulations 1992, BS EN 12453:2001 and BS EN 12445:2001 it is highly recommended that the following items are fitted to your automatic sliding gate.
Safety edge to leading edge of gate leaf – to prevent gates closing on a person or vehicle when the gate is activated.
Additional safety edges to internal and external motor posts
Weldmesh infill
Post mounted audible alarm or flashing beacon, alerting people when the gate is in operation
Pedestrian guard rail around run-back area. This is to prevent injury to a person, should they stray into that area whilst the sliding gates are operating.
Safety induction loops cut into the road surface. This will inhibit automatic sliding gates closing on to a vehicle within the aperture, if detected.
Safety photocells and laser scanners act as additional safety for pedestrians and high lorries.

Forces:
A maximim of 400N of crushing force is permitted before the gate leaf should start to reverse, for gaps greater than 500mm a maximum crushing force of 1400N is permitted. Regular maintenance and force testing is recommended by a trained technician.

  • Access control and intercom systems
  • Audible alarm / Flashing beacon
  • Safety edge / Safety photocells / Laser scanners
  • Serrated / barbed wire/wire toppings
  • High-speed gate drive
  • Pedestrian guard rail
  • Inductive loop systems
  • Traffic lights & back indications systems
  • Matching infills and cladding
  • High quality coating system
  • Galvanised/Zinc sprayed and powder/plastic coated
  • Manual override facility
  • Bespoke built units
  • Environmentally durable
  • Custom built to client specification
  • Ease of installation
  • Operational under power failure conditions

Basic Power Requirements:
230v Single phase 50Hz supply 230V/400V 3 phase (option) 110V (option). The incoming mains supply to the control panel is normally single- phase 220/250 V, but three phase 400V may be required depending on the design length and weight of the gate.

Control:
Basic gate is a push button – hold to run, alternative access control systems can be accommodated.

Dimensions:
Dimensions range from 3m to 12m Clear width openings and heights are normally 2.1m or 2.4m, infills and panels available are dependant on height and weight of gate.

Safety:
When deciding to install a sliding gate A full site risk assessment should be undertaken prior to the design and installation of the gate, to ensure that all the appropriate safety measures have been addressed:

Safety Options – In accordance with the workplace (Health, Safety and Welfare) regulations 1992, BS EN 12453:2001 and BS EN 12445:2001 it is highly recommended that the following items are fitted to your automatic sliding gate.
Safety edge to leading edge of gate leaf – to prevent gates closing on a person or vehicle when the gate is activated.
Additional safety edges to internal and external motor posts
Weldmesh infill
Post mounted audible alarm or flashing beacon, alerting people when the gate is in operation
Pedestrian guard rail around run-back area. This is to prevent injury to a person, should they stray into that area whilst the sliding gates are operating.
Safety induction loops cut into the road surface. This will inhibit automatic sliding gates closing on to a vehicle within the aperture, if detected.
Safety photocells and laser scanners act as additional safety for pedestrians and high lorries.

Forces:
A maximim of 400N of crushing force is permitted before the gate leaf should start to reverse, for gaps greater than 500mm a maximum crushing force of 1400N is permitted. Regular maintenance and force testing is recommended by a trained technician.

  • Access control and intercom systems
  • Audible alarm / Flashing beacon
  • Safety edge / Safety photocells / Laser scanners
  • Serrated / barbed wire/wire toppings
  • High-speed gate drive
  • Pedestrian guard rail
  • Inductive loop systems
  • Traffic lights & back indications systems
  • Matching infills and cladding

Some of our clients

Microsoft Logo
Hilton Zurich Airport Logo
Kemba Credit Union Logo
Hanover Bank Logo
Spisestuerne Logo
Bouwmaat Logo