Designed for vehicle control in hazardous areas

EX750 Rising Arm Barriers are an ATEX / IECEx certified product that have been designed for vehicle control in hazardous areas which are potentially susceptible to explosive atmospheres.

Designed and manufactured in the UK, EX750 Barriers will provide vehicle access and movement control for primarily oil and gas / chemical works sites without creating an ignition source.

The EX750 is a vehicle control barrier that has been specifically designed to mitigate the Health and Safety risks associated with sites with the potential for the build-up of explosive atmospheres.

EX750 Rising Arm Barriers are an ATEX / IECEx certified product that have been designed for vehicle control in hazardous areas which are potentially susceptible to explosive atmospheres.

Designed and manufactured in the UK, EX750 Barriers will provide vehicle access and movement control for primarily oil and gas / chemical works sites without creating an ignition source.

The EX750 is a vehicle control barrier that has been specifically designed to mitigate the Health and Safety risks associated with sites with the potential for the build-up of explosive atmospheres.

Ex750barrier

Key Features

  • Dot Independently certified
  • Dot ATEX / IECEx certified for use up to zone 1 and 2
  • Dot Produced by certified IECEx manufacturer
  • Dot Category 2G
  • Dot 100% Duty cycling
  • Dot Low maintenance

The EX750 CAT2 Barrier can operate in an area that is deemed to be a potentially explosive atmosphere, an explosive atmosphere can be caused by flammable gases, mists or vapors or by combustible dust. When these dangerous substances combine with air, under atmospheric conditions and ignition has occurred, the combustion spreads to the entire unburned mixture.

How to reduce the risk of an explosion?

Many workplaces may contain, or have activities that produce explosive or potentially explosive atmospheres. Examples include places where work activities create or release flammable gases or vapors, such as vehicle paint spraying, or in workplaces handling fine organic dust such as grain flour or wood.

  • Prevention & Reduction of the number of dangerous substances that cause the explosive atmosphere
  • Prevent ignition source

Mechanical & electrical equipment that operates in zoned areas should comply with the requirement of the ATEX directive & the IECEx standard

  • ATEX / IECEx certified
  • Certified for use up to Zone 1&2
  • Category 2G
  • Gas Group IIB
  • Robust Construction
  • Independently certified
  • Produced by certified IECEx manufacturer
  • 100% Duty cycling
  • Low maintenance

Physical Dimensions: Barrier Cabinet – 1130mm H x 500mm W x 305mm D

Basic Power Requirements: 230v, 1ph, 6amp, 50HZ (Other voltages are available on request)

Control Voltage: S.E.L.V 24v

ATEX certified protection level: II 2G IIB c T3

IECEx certified protection level: Ex h IIB T3 Gb

Speed of operation: 4.2 seconds to raise/lower cycle

Approx weight: 130kg

Paint finish: INVER S.P.A. 40496 NP ESD Rosso 3001 (red), thickness 80 microns (anti-static paint)

Boom profile – Rectangular extruded aluminium 76 x 38mm white powder coated with red fascal striping (black and yellow
option available) Max length 5m. Booms are mounted on the right hand (as standard unless specified)

Barrier arm: The barrier arm is constructed from 76 x 38mm aluminium, white powder coated with reflective red striping.
Booms are mounted on the right side of the barrier as viewed from the back of the cabinet.

Power fail operation: Manual hand wind

IP & Electrical protection level:
The barrier comes with an IP66, ATEX / IECEx Ex d explosion proof certified enclosure to enclose the control system

  • ATEX / IECEx certified
  • Certified for use up to Zone 1&2
  • Category 2G
  • Gas Group IIB
  • Robust Construction
  • Independently certified
  • Produced by certified IECEx manufacturer
  • 100% Duty cycling
  • Low maintenance

Physical Dimensions: Barrier Cabinet – 1130mm H x 500mm W x 305mm D

Basic Power Requirements: 230v, 1ph, 6amp, 50HZ (Other voltages are available on request)

Control Voltage: S.E.L.V 24v

ATEX certified protection level: II 2G IIB c T3

IECEx certified protection level: Ex h IIB T3 Gb

Speed of operation: 4.2 seconds to raise/lower cycle

Approx weight: 130kg

Paint finish: INVER S.P.A. 40496 NP ESD Rosso 3001 (red), thickness 80 microns (anti-static paint)

Boom profile – Rectangular extruded aluminium 76 x 38mm white powder coated with red fascal striping (black and yellow
option available) Max length 5m. Booms are mounted on the right hand (as standard unless specified)

Barrier arm: The barrier arm is constructed from 76 x 38mm aluminium, white powder coated with reflective red striping.
Booms are mounted on the right side of the barrier as viewed from the back of the cabinet.

Power fail operation: Manual hand wind

IP & Electrical protection level:
The barrier comes with an IP66, ATEX / IECEx Ex d explosion proof certified enclosure to enclose the control system