ClearSec FOS

ClearSec FOS

Manual Full-Height-Turnstile for Internal and External Installation

ClearSec FOS 90 is a robust and elegant full-height turnstile including a protective roof with water draining system and way mode indicator lights. Delivered as mono-bock and self supporting, it is easily installed and ideal for applications requiring high performance combined with a full stainless steel construction and transparent design.

Applications areas include that of Government buildings, retail, finance hubs, telecommunications, IT, Banking, Publishing, Leisure, Petrochemical and education sector, etc.

Key Benefits at a Glance

  • Card reader integration
  • Switching interface COMR1
  • Serial interface RS485
  • Remote console
  • Internal lighting
  • Extra Canopy

Product Overview

Full Height Turnstile for Internal & External Installation

Passage in both directions electronically controlled. ClearSec FOS 90 offers a standard electromechanical head able to prevent two passages at one time, equipped with damper for a silent mechanism and smooth operation.
In the event of an emergency or power-off scenario, the unit can be configured fail-safe i.e. rotor freely  rotates or fail-lock i.e. rotor locks. This option is available either in one or both directions of passage.

Mechanism

Electro-mechanical head mechanism:

  • Positive action lock to prevent two passages at one time
  • Self centering mechanism to ensure complete rotation in the rest position
  • Anti backup device to prevent reverse rotation once the head moved 30° from rest position
  • Hydraulic damper to ensure a smooth and quiet operation

Power Failure / Fire Alarm

In the event of a power failure the rotor wings will remain locked in the fail-lock configuration or can freely rotate in the fail-safe configuration. Fail-Lock or Fail- Safe configuration is available in one or both directions and must be specified at time of order placement. Note that head mechanism fail state will be the same as power failure choice. Input facility available for voltage free contact to effect fire alarm fail state (COMR1 option required)

Power Failure / Fire Alarm
In the event of a power failure the rotor wings will remain locked in the fail-lock configuration or can freely rotate in the fail-safe configuration. Fail-Lock or Fail- Safe configuration is available in one or both directions and must be specified at time of order placement. Note that head mechanism fail state will be the same as power failure choice. Input facility available for voltage free contact to effect fire alarm fail state (COMR1 option required)

Power Supply / Power Rating

230Vac 50Hz or 115Vac 60Hz
Power Rating 50VA, 50 + 50 VA for Double unit Without lights option

Operating Temperature / IP Rating / MCBF / MTTR

-5 to +50°C (RH 95% not condensing) / IP34 / 1.5M cycles / less than 30min

Flow Rates (approximate figures)

  • Insertion Type Reader, 12 passages per minute
  • Swipe Type Reader, 15 passages per minute
  • Proximity Reader “Hands Free”, 17 passages per minute
Drive Hand operated. Logic Voltage 24Vac
Casework: 304 Grade stainless steel with infill glass panels (5+5security glass)
Rotor Wings: 304 Grade stainless steel
Rotor Spindle: 304 Grade stainless steel
Floor Covering: Black rubber floor mat